ubuntuusers.de

🚧 Am Sonntag, 5. Mai, werden ab 16 Uhr die Server aktualisiert und eine neue Inyoka-Version veröffentlicht. Das Portal wird mehrmals nicht verfügbar sein.

Smart Ausgabe

Autor:
ole8000
Datum:
16. August 2008 18:24
Code:
 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
~$ sudo smartctl -d ata -a /dev/sda -F samsung
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG HM160HI
Serial Number:    S14QJF0PA28845
Firmware Version: HH100-10
User Capacity:    160.041.885.696 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 0
Local Time is:    Sat Aug 16 18:10:36 2008 CEST

==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details.

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		 (  60) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  60) minutes.
SCT capabilities: 	       (0x003f)	SCT Status supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail  Always       -       4
  3 Spin_Up_Time            0x0007   252   252   025    Pre-fail  Always       -       2000
  4 Start_Stop_Count        0x0032   084   084   000    Old_age   Always       -       167940
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       1
  9 Power_On_Hours          0x0032   095   095   000    Old_age   Always       -       3112
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       918
191 G-Sense_Error_Rate      0x0032   094   094   000    Old_age   Always       -       65698
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       94
194 Temperature_Celsius     0x0022   106   094   000    Old_age   Always       -       44 (Lifetime Min/Max 10/48)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       144182
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       3473
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       7240
199 UDMA_CRC_Error_Count    0x0036   252   252   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x000a   252   252   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
SMART Selective self-test log data structure revision number 0
Warning: ATA Specification requires selective self-test log data structure revision number = 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed [00% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.