trian@paracelsus:~$ sudo smartctl /dev/sda --all [sudo] password for trian: smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Momentus family Device Model: ST94011A Serial Number: 3KW0PC6H Firmware Version: 3.04 User Capacity: 40.007.761.920 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 2 Local Time is: Mon Aug 11 03:11:27 2008 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 121) The previous self-test completed having the read element of the test failed. Total time to complete Offline data collection: ( 426) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 31) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 056 051 034 Pre-fail Always - 233333566 3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 92 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 37 7 Seek_Error_Rate 0x000f 061 060 030 Pre-fail Always - 210518707652 9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 6695 10 Spin_Retry_Count 0x0013 100 098 000 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 098 098 020 Old_age Always - 2079 192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 2994 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 387392 194 Temperature_Celsius 0x0022 053 059 000 Old_age Always - 53 195 Hardware_ECC_Recovered 0x001a 056 051 000 Old_age Always - 233333566 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 169 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 169 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 099 252 000 Old_age Always - 1 SMART Error Log Version: 1 ATA Error Count: 1585 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 1585 occurred at disk power-on lifetime: 6647 hours (276 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 6a 18 69 e2 Error: UNC at LBA = 0x0269186a = 40441962 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 69 18 69 e2 00 01:02:13.554 READ DMA c8 00 08 f9 8c 54 e2 00 01:02:13.553 READ DMA c8 00 18 d1 70 59 e2 00 01:02:13.544 READ DMA c8 00 38 81 02 65 e2 00 01:02:13.529 READ DMA c8 00 50 31 02 65 e2 00 01:02:13.529 READ DMA Error 1584 occurred at disk power-on lifetime: 6647 hours (276 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 6a 18 69 e2 Error: UNC at LBA = 0x0269186a = 40441962 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 20 61 18 69 e2 00 01:01:59.948 READ DMA 27 00 00 00 00 00 e0 00 01:01:59.940 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 02 01:01:59.940 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 01:01:59.933 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 01:01:54.203 READ NATIVE MAX ADDRESS EXT Error 1583 occurred at disk power-on lifetime: 6647 hours (276 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 6a 18 69 e2 Error: UNC at LBA = 0x0269186a = 40441962 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 20 61 18 69 e2 00 01:01:59.948 READ DMA 27 00 00 00 00 00 e0 00 01:01:59.940 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 02 01:01:59.940 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 01:01:59.933 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 01:01:54.203 READ NATIVE MAX ADDRESS EXT Error 1582 occurred at disk power-on lifetime: 6647 hours (276 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 6a 18 69 e2 Error: UNC at LBA = 0x0269186a = 40441962 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 20 61 18 69 e2 00 01:01:48.331 READ DMA 27 00 00 00 00 00 e0 00 01:01:42.542 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 02 01:01:42.542 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 01:01:42.534 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 01:01:54.203 READ NATIVE MAX ADDRESS EXT Error 1581 occurred at disk power-on lifetime: 6647 hours (276 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 6a 18 69 e2 Error: UNC at LBA = 0x0269186a = 40441962 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 20 61 18 69 e2 00 01:01:48.331 READ DMA 27 00 00 00 00 00 e0 00 01:01:42.542 READ NATIVE MAX ADDRESS EXT ec 00 00 00 00 00 a0 02 01:01:42.542 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 01:01:42.534 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 e0 00 01:01:42.526 READ NATIVE MAX ADDRESS EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: read failure 90% 6578 66090149 # 2 Extended offline Completed: read failure 90% 6352 9340730 # 3 Extended offline Completed: read failure 90% 6350 9340730 # 4 Short offline Completed without error 00% 6348 - # 5 Short offline Completed without error 00% 6293 - # 6 Short offline Completed without error 00% 6105 - # 7 Short offline Completed without error 00% 6087 - # 8 Short offline Completed without error 00% 6082 - # 9 Short offline Completed without error 00% 6061 - #10 Extended offline Completed: read failure 90% 5993 9340012 #11 Short offline Completed without error 00% 5992 - #12 Short offline Completed without error 00% 5992 - #13 Short offline Completed without error 00% 5242 - #14 Short offline Completed without error 00% 5240 - #15 Short offline Completed: read failure 90% 5239 9340036 #16 Extended offline Completed: read failure 90% 5233 9340036 #17 Short offline Completed: read failure 90% 5232 9340036 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.